Perspectives in Medical Research

Volume: 7 Issue: 2

  • Open Access
  • Original Article

Efficacy of optic nerve sheath diameter by ultrasound as a non-invasive method to determine elevated intracranial pressure in Indian population.

Mhatre M1, Baviskar A2 Dongre H3, Rajpal D4

Address for correspondence: Dr Ajit Baviskar, Department of Emergency Medicine, Dr. D.Y. Patil Medical College, Navi Mumbai.
E mail ID: - [email protected]

Year: 2019, Page: 38-42,

Abstract

Introduction: It is important to assess use of Optic Nerve sheath Diameter (ONSD) measurement by point of care ultrasonography (POCUS) as a non-invasive method for detecting elevated Intracranial Pressure (ICP) and to compare with Brain Computed Tomography (CT) findings of Elevated ICP in Indian population
Methods: This study was a Prospective Observational Study done in emergency Department of a tertiary care hospital in western India .Adult patients within 18-60 years age group, with Head trauma presenting with headache, vomiting, convulsions, loss of consciousness, and altered sensorium were included in the study.Non-trauma patients with focal neurological changes and history suggestive of possible spontaneous intracranial hemorrhage were also included. Data was recorded after stabilizing patients as per standard trauma and non-trauma protocol.
Patients underwent a POCUS study to measure the ONSD. Based on clinical judgment and ONSD measurement above the expected cut-off range, medical management for Elevated ICP was started. A Plain Brain CT Scan was obtained. Definitive treatment was planned after confirming on CT scan.
ONSD measurement more than 6mm was suggestive of Elevated ICP
Results: 108 patients were studied. A normal range of ONSD found was 3.5mm – 5.4mm.
26 patients had CT results consistent with Elevated ICP. All cases of CT-determined Elevated ICP were correctly predicted by ONSD.The sensitivity and specificity of this study is 98.75 % and 92.86% respectively.
Conclusion: POCUS has the advantages of cost, time effective, non-invasive and reproducibility. It can be used as an additional diagnostic tool.

Keywords: Optic nerve sheath diameter, Point of care Ultrasound, Intracranial pressure

References

1. Centers for Disease Control and Prevention: Vital Statistics. Available at: http:// www.cdc.gov/nchs/vitalstats.htm. Accessed December 22, 2008.
2. Robertson CS: Management of cerebral perfusion pressure after traumatic brain injury. Anesthesiology 95(6): 1513, 2001.
3. Hovda DA: Oxidative need and oxidative capacity following traumatic brain injury. Crit Care Med 35(2): 663, 2007.
4. Chesnut RM: Care of central nervous system injuries. Surg Clin North ?Am 2007; 87:119-156, vii.
5. Shevlin C. Optic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential. Critical Care Horizons 2015; 1: 22-30.?
6. Hayreh SS. Pathogenesis o edema of the optic disc. Doc Ophthalmol. 1968; 24:289-411.
7. Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, Blaivas M. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med. 2007;49(4):508–514.
8. Hwan Kim Y, Ho Lee J, Kun Hong C,Won Cho K, Hoon Yeo J, Ju Kang M, et al. Feasibility of optic nerve sheath diameter measured on initial brain computed tomography as an early neurologic outcome predictor after cardiac arrest. Acad Emerg Med. 2014;21(10):1121–1128.
9. Legrand A, Jeanjean P, Delanghe F, Peltier J, Lecat B, Dupont H. Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients. Crit Care. 2013;17(2):R61.
10. Nabeta HW, Bahr NC, Rhein J, Fossland N, Kiragga AN, Meya DB, et al. Accuracy of noninvasive intraocular pressure or optic nerve sheath diameter measurements for predicting elevated intracranial pressure in cryptococcal meningitis. Open Forum Infect Dis. 2014;1(3):ofu093.
11. Shirodkar CG, Rao SM, Mutkule DP, Harde YR, Venkategowda PM, Mahesh MU. Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study. Indian J Crit Care Med. 2014;18(11):728–734.
12. Kim YK, Seo H, Yu J, Hwang GS. Noninvasive estimation of raised intracranial pressure using ocular ultrasonography in liver transplant recipients with acute liver failure -A report of two cases-. Korean J Anesthesiol. 2013;64(5):451–455.
13. Manno E, Motevallian M, Mfochive A, Navarra M. Ultrasonography Of The Optic Nerve Sheath Suggested Elevated Intracranial Pressure In Epilepsy: Case Report. Internet J Anesthesiol. 2013;26(1).
14. Blaivas M, Theodoro D, Sierzenski PR. Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath. Acad Emerg Med. 2003;10(4):376–381.
15. Geeraerts T, Launey Y, Martin L, Pottecher J, Vigué B, Duranteau J, et al. Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med. 2007;33(10):1704–1711.
16. Qayyum H, Ramlakhan S. Eur J Emerg Med. 2013 Apr;20(2):91-7. Doi: 10.1097/MEJ

Cite this article

Mhatre M, Baviskar A, Dongre H, Rajpal D. Efficacy of optic nerve sheath diameter by ultrasound as a non-invasive method to determine elevated intracranial pressure in Indian population. Perspectives in Medical Research 2019; 7(2):38-42.

Views
248
Downloads
157